Road Metro Station Tunnel Booster Fan

Road Metro Station Tunnel Booster Fan

High pressure high temperature centrifugal fan,The fan has 7 types of machines (4C-12.4D) Applicable range It is suitable for 1-20 tons / h industrial boiler induced air with the highest efficiency of 90.5%, and the highest temperature shall not exceed 250 ° C. The draft fan itself has high...
Send Inquiry
Product Introduction

Our company adopts a unique production process and production technology. Our potterton fan, High Temperature Fan, high temp blower have excellent and stable performance, complete models and exquisite packaging. This industry is booming, thus our company has immeasurable potential in the long run and we will achieve good performance. We focus on providing service for our clients as a key element in strengthening our long-term relationships. Improving corporate governance is a fundamental project to enhance the core competitiveness of enterprises. We will keep you informed of our progress and look forward to building steady business relations with you.

Industrial Dust Fan:

Industrial dust fan, the fan has 7 types of machines (4C-12.4D)
Applicable range
It is suitable for 1-20 tons / h industrial  boiler-induced air with the highest efficiency of 90.5%,  and the highest temperature shall not exceed 250 ° C.Industrial Dust Fan,the draft fan itself has high strength and  wear resistance, as well as long service life.
Performance parameters:
Flow Q: 45-1255.5m³ /mm
Full pressure P: 990-3854Pa
Power N: 3-90KW

4

Performance  parameter of Y5-47 boiler centrifugal induced draft fan


Machine No.

Rotate speed    r/min

Full pressure (Pa)

Flow (m3/h)

Power (KW)

Motor model

4C

2900

990-1451

2750-5060

3

Y100L-2

4C

3300

1285-1873

3130-5750

4

Y112M-2

5C

2900

1549-2265

5360-9870

7.5

Y132S2-2

5C

2920

1265-1844

4840-8900

5.5

Y132S1-2

6C

2850

3148

9110-10200

15

Y160M2-2

6C

2850

2148-3148

11300-16760

18.5

Y160L-2

6C

2620

1824-2658

8370-15410

15

Y160M2-2

8C

1820

2530

13780-15430

18.5

Y180M-4

8C

1820

1726-2501

17080-25360

22

Y180L-4

8C

1980

2050-2991

15000-27600

30

Y200L-4

9C

1740

2001-2922

18780-34550

37

Y225S-4

9C

1820

2903-3197

19640-29070

37

Y225S-4

9C

1820

2187-2736

31420-36140

45

Y225M-4

12D

1450

2471-3609

37100-68250

75

Y280S-4

12.4D

1450

2638-3854

40940-75330

90

Y280M-4

5

So what are the advantages of using an Industrial Dust Fan?

First of all, the function of the industrial dust fan is to use the high-speed rotating impeller to accelerate the gas, and then decelerate and change the direction to promote the conversion of kinetic energy into potential energy. Secondly, the flow rate of the high-pressure centrifugal fan is much larger than that of the high-pressure fan, in addition, the high-pressure centrifugal fan can overfeed, and has the effect of exhausting air and dust removal!

The noise of the second high-pressure centrifugal fan is relatively low, and its service life is relatively long.

High-pressure centrifugal fans are widely used in forging furnaces, glass, electroplating, ceramics, batteries, radio and other industries for high-pressure forced air supply and exhaust, material transportation in grain, feed, mineral powder and other processing industries, carton machinery and equipment, tempered glass equipment and other supporting uses; and the transportation of non-corrosive, non-spontaneous combustion, no viscous substances of gas.


We are committed to integrity and service. In the future, we will cherish the trust of customers, continue to optimize products and improve service levels, and return customers with high-quality Road Metro Station Tunnel Booster Fan. Sincerity is our commitment to the majority of consumers and is also the cornerstone of win-win between enterprises and partners. We are committed to social responsibility in order to earn the respect and trust of all sectors of society.

Send Inquiry

whatsapp

Phone

E-mail

Inquiry