Industrial Small Air Centrifugal Blower Ventilator Fan and Exhaust Fan
We use excellent production equipment, advanced production technology and scientific management methods to ensure the excellent quality of our Mine Underground Explosion-proof Induced Draft Fan, Explosion-proof Axial Fan, Coal Mine Explosion-proof Blower. We are expecting to cooperate with you on the basis of mutual benefits and common development. By strengthening the strength of employees, we create extraordinary value for customers and the industry. We sincerely hope to serve more new and old customers and friends at home and abroad. Your satisfaction is our greatest wish. We are willing to create more wealth for you with our hands and wisdom.
Centrifugal Blower Fan:
High-temperature boiler induced draft fan
The usage of the ventilator
The model G, Y6-41 boiler Centrifugal Blower Fan and induced draft fan are designed for adapting the industrial boiler that burns a variety of coal and is equipped with dust and smoke removal devices. The new series of low-noise boiler drums and induced draft fans with the highest total pressure efficiency of higher than 80% can be selected by all the items with the equivalent intake conditions and suitable performance.

The features of the ventilator
The model G, Y6-41 series centrifugal ventilator is a replacement product of the boiler drum and induced draft fan.
The design method of the model G, Y6-41 series ventilator follows the design principles of selecting the appropriate ventilator type, reasonable operating parameters and preferred flow pattern, organizing the gas source reasonably, designing the blade type carefully, increasing the gap of wind tongue, reducing the rotate speed appropriately, improving the volute design, purifying flow and minimizing the secondary flow loss as much as possible, etc. Moreover, conduct optimal design for the wind gap by the combination of using the finite difference method for the numerical calculation of the air inlet and impeller cap lines and taking the flow field uniformity at the fan impeller inlet as the optimization criterion. Then, combine the above method with the original optimized design method of fan impeller and volute to integrate the optimal design procedure of impeller, volute and air inlet with a lower noise level and smaller size of the fan.

Centrifugal Blower Fan,The model G and Y6-41 series ventilators have been tested by Shenyang Blower Research Institute and have achieved good results. The test data is quoted as follows:
Induced draft fan: Y6-41-11No7.1C matched with 4 tons / hourly coal-fired boiler:
Working temperature: 200 ° C; rotate speed: 2100 rev / min
Design operating parameters: flux: 12500 m³ / h; full pressure: 2596 Pa
Our company has a professional technical management team, rich production experience, perfect management system, and is one of the best Chinese manufacturers of Industrial Small Air Centrifugal Blower Ventilator Fan and Exhaust Fan. We have professional production experience, strong production technology and market foundation. With the purpose of 'trying to be better', we are committed to technical innovation and product development, providing customers with new and high-performance products.