OEM Explosion-Proof Mining Fan/Mine Fan for Ventilation in Underground Coal Mine Work
Like a result of ours specialty and repair consciousness, our enterprise has won a superb popularity amid buyers everywhere in the environment for Roof Axial Flow Fan, Subway Tunnel Fan, Mine Press-in Counter-rotating Fan. We hope to create conditions conducive to the stable development of the enterprise by building up a warm and harmonious working environment. Our company regards quality as the life of the enterprise, strictly checks every link and provides customers with the best quality and reliable products. We will continue to work hard, be determined to innovate, meet customer needs, and measure our success by customer success! 'Making the Products of High Quality' is the eternal goal of our company.
Coal mine explosion-proof fan FBCDZ (formerly BDK62) series of fans have a total of 24 machine numbers of NO.14-NO.44. To meet the needs of large and medium-sized mines with various kinds of ventilation network parameters, this series of fans are respectively equipped with 6, 8, 10, 12-pole three-phase asynchronous motors, and two different types of blade number gradations are adopted: that is, the total number of FBCDZ (formerly BDK62) (A) blades is Z = 32 pieces, and the total number of FBDCZ (formerly BDK62) (B) blades is Z = 24 pieces. Through the above combination, the FBCDZ (formerly BDK62) series of fans have a total of 90 specifications. It solves the problem that the main fan model of the mine is small and the selection is difficult.

The ground of the fan installation site should be flat, and according to the gauge in the sample schematic diagram, the auxiliary steel rail should be set, and the 24-38 Kg / M light rail can be selected and used. The steel rail can be pre-embedded on the cement floor surface or fixed on the sleeper.
The explosion-proof type of fan: the explosion-proof type for coal mine
If the motor power required in the early and the later stages of the mine is greatly different, it can be compared economically. In the early stage, two motors with smaller power are equipped, and in the later stage the motors are replaced with high-power ones. In this way, the motors can be operated under the condition of a higher power factor and higher efficiency, to reduce electricity consumption and save electricity costs.
The design service life of the FBCDZ (formerly BDK) series of fans is 20 years.
Series | No. | Air volume (m3/s) | Full pressure(Pa) | Motor model | Power (KW) |
FBCDZ(B)-8 (n=740r/min) | 27 | 63.7-161.0 | 1488-4313 | YBF560S2-8 | 2×355 |
28 | 71.1-179.8 | 1600-4638 | YBF560M2-8 | 2×450 | |
FBCDZ(B)-10 (n=590r/min) | 21 | 23.9-60.5 | 572-1659 | YBF315L-10 | 2×75 |
22 | 27.5-69.5 | 628-1820 | YBF315L-10 | 2×75 | |
23 | 31.4-79.5 | 686-1990 | YBF355M1-10 | 2×90 | |
24 | 35.7-90.3 | 747-2166 | YBF355M2-10 | 2×110 | |
25 | 40.3-102.1 | 811-2351 | YBF355L2-10 | 2×160 | |
26 | 45.4-114.8 | 877-2542 | YBF355L3-10 | 2×185 | |
27 | 50.8-128.6 | 946-2742 | YBF450S3-10 | 2×200 | |
28 | 56.7-143.4 | 1017-2949 | YBF450M2-10 | 2×250 | |
29 | 63.0-159.3 | 1091-3163 | YBF450M2-10 | 2×250 | |
30 | 69.7-176.4 | 1168-3385 | JBO710M1-10 | 2×315 | |
32 | 84.6-214.0 | 1329-3851 | JBO800S2-10 | 2×450 | |
34 | 101.5-256.7 | 1500-4348 | JBO900S1-10 | 2×560 | |
36 | 120.4-304.7 | 1682-4874 | JBO900M1-10 | 2×710 | |
FBCDZ(B)-12 (n=490r/min) | 25 | 33.5-84.8 | 559-1621 | JBO355S2-12 | 2×110 |
26 | 37.7-95.3 | 605-1754 | JBO355S2-12 | 2×110 | |
27 | 42.2-106.8 | 652-1891 | JBO400S-12 | 2×132 | |
28 | 47.1-119.1 | 702-2034 | JBO400M-12 | 2×160 | |
29 | 52.3-132.3 | 753-2182 | JBO400M-12 | 2×160 | |
30 | 57.9-146.5 | 806-2335 | JBO710S1-12 | 2×200 | |
32 | 70.3-177.7 | 916-2656 | JBO710M1-12 | 2×250 | |
34 | 84.3-213.2 | 1035-2999 | JBO800S1-12 | 2×315 | |
36 | 100.0-253.1 | 1160-3362 | JBO900S1-12 | 2×450 | |
38 | 117.6-297.6 | 1292-3746 | JBO900M1-12 | 2×560 | |
40 | 137.2-347.2 | 1432-4150 | JBO900M2-12 | 2×710 | |
42 | 158.8-401.9 | 1579-4576 | JBO900L2-12 | 2×1000 | |
44 | 182.6-462.1 | 1733-5022 | JBO900L3-12 | 2×1250 |

We insist on the principle of development of 'High quality, Efficiency, Sincerity and Down-to-earth working approach' to provide you with excellent service of processing for OEM Explosion-Proof Mining Fan/Mine Fan for Ventilation in Underground Coal Mine Work. Our items have been obtained more and more recognition from foreign clients, and established long term and cooperative relationship with them. We reject fantasies, oppose paper talk, and pursue a substantial and energetic management approach.