Mine explosion-proof blower The main technical performance parameters of this series of fans are: air volume Q, full pressure P, full pressure efficiency η, noise (compared with A sound level) LSA, rotating speed n and so on. The maximum efficiency of the series of fans is 86%, and the highest...
Send Inquiry
Product Introduction

For technology, we tirelessly pursue breakthroughs, put customer needs first, and strive to develop new Centrifugal Fan For Power Plant, Dust Removal Centrifugal Fan, Fan Blower. We continuously strengthen operation management, enhance corporate image, optimize product structure, improve product quality, and establish product quality assurance system. We stick to the service concept of "focus on customers, exceed expectations", and we have a huge sales network covering multiple regions.

Mine explosion-proof blower  The main technical performance parameters of this series of fans are: air volume Q, full pressure P, full pressure efficiency η, noise (compared with A sound level) LSA, rotating speed n and so on. The maximum efficiency of the series of fans is 86%, and the highest noise does not exceed 85dB(A).  See Table 1 for details of other parameters.

16

This product can be placed flat on the floor of the roadway, and also can be suspended on the wall of the roadway for use. When used on the floor, the air inlet (the collector end) of the fan should not be immersed in water or cement. The gas temperature of the user environment of the fan is -20~50℃, and the altitude should not exceed 1000m. The rated frequency of the power supply used is 50 Hz, and the rated voltage is any class of 380V/660V or 660V/1140V.


The dust content of the gas passing through this product does not exceed 200mg/m3. It should be installed in the air inlet with a gas concentration of less than 1% in the underground coal mine. When the gas concentration exceeds 1%, the power supply should be cut off immediately.



Serial no.

Machine no.

Air volume (m3/min)

Full pressure (Pa)

Power (KW)

1

3.5/4.4

133-90

715-1320

2.2×2

2

4/3

111-56

172-1800

1.5×2

3

4/4.4

136-72

251-1880

2.2×2

4

4/6

150-86

351-1956

3×2

5

5/8

210-120

331-2503

4×2

6

5/11

228-132

371-2950

5.5×2

7

5/15

245-150

380-3524

7.5×2

8

5.6/15

274-164

375-3750

7.5×2

9

5.6/22

340-210

405-4418

11×2

10

5.6/30

395-250

450-4470

15×2

11

6.3/30

420-260

413-4950

15×2

12

6.3/37

486-292

513-5130

18.5×2

13

6.3/44

525-310

600-5263

22×2

14

6.3/60

590-390

760-5800

30×2

15

7.1/60

620-396

603-6450

30×2

16

7.1/74

672-480

800-6500

37×2

17

7.1/90

738-400

1100-6700

45×2

18

8.2/74

630-270

420-6900

37×2

19

8.2/90

654-380

600-7600

45×2

20

8.2/110

790-550

680-8200

55×2

21

8.2/150

964-546

700-8600

75×2

22

10/60

1170-814

745-2733

30×2

18

Skilled skilled knowledge, strong sense of company, to meet the company wants of customers for Mining Disrotatory Axial Exhaust Blower with Sillencer Tunnel Axial Fan. We usually continually offer you the most conscientious consumer services, along with the widest variety of designs and styles with finest materials. We are a company that integrates research and development, technical consulting services and production and management.