The FBCD series includes 18 machine numbers. For detailed information, please refer to the structure diagram of the FBCD series of coal mine extraction type counter-rotating axial flow partial ventilator. The aerodynamic performance parameters under the standard conditions are shown in Table 1.
Send Inquiry
Product Introduction

We are committed to integrity and service. In the future, we will cherish the trust of customers, continue to optimize products and improve service levels, and return customers with high-quality Mining Extraction Type Local Ventilator, Indoor Axial Fan, Mine Ventilation Blower. In case you are intrigued in any of our products or want to focus on a personalized get, please sense totally free to contact us. We adhere to the tenet of quality for survival and innovation for development, and vigorously introduces domestic and foreign talents, technology and production equipment. We firmly believe that as long as we take the market as the guidance, take the innovation as the driving force, take the quality as the cornerstone and take the creation of the first-class enterprise as the goal, we will surely win a better tomorrow. We build mutually beneficial relationship with our clients by giving them large selection of premium car parts at marked down prices.

Booster Fan Duct Booster Fan:

Booster fan duct booster fans are generally used in forging furnaces and high-pressure forced ventilation. The gas does not contain viscous substances, the dust and hard particles contained do not exceed 150mg/m3, and the gas temperature is 20-800 °C.
Booster fan duct booster fans can fansfan be made into two types: right-handed and left-handed. From the side of the motor, if the impeller rotates clockwise, it is called a right-handed fan, denoted by "right"; the impeller rotating counterclockwise is called a left-handed fan, denoted by "left".
The position of the air outlet of the fan is expressed by the angle of the air outlet of the casing. "Left" and "Right" can be made into six angles of 0°, 45°, 90°, 135°, 180°, and 225°.
Before installation: All parts of the fan should be checked comprehensively, whether the parts are complete, whether the rotation direction of the impeller and the casing are consistent, and whether the connection of each part is tight. Whether the impeller, main shaft, bearing, and other main parts are damaged, whether the transmission group is flexible, etc.

5

When installing: pay attention to checking the casing, and there should be no tools and debris left in the casing. To prevent rust and reduce the difficulty of disassembly on some joint surfaces, some grease or mechanical oil should be coated. The connection surface between the fan and the foundation, the inlet, and the outlet ducts should be adjusted to match naturally, and the connection should not be forced and is not allowed to add the weight of the duct to each part of the fan. And pay attention to ensure the horizontal position of the fan.

6

Booster fan duct booster fan installation requirements:
(1) Install according to the position and size are shown in the drawing. To ensure high efficiency, ensure the axial and radial clearance between the air inlet and the impeller.
(2) After installation, try dialing the transmission group to check whether it is too tight or collides with the fixed part.
(3) After all installations are completed and the general inspection is passed, the test operation of the fan can be carried out.
To prevent the motor from being overloaded and burned, when the fan starts, it must be carried out under no load (close the air inlet valve and open the air outlet valve slightly). If the condition is good, gradually open the valve until the specified working condition. During operation, the current should be strictly controlled and the rated value should not be exceeded.



This is the result of our long-term unremitting efforts in the development of new Industrial FRP Fiber Glass Cone Ventilation Exhaust Fan for Poultry House/Industrial Workshop/Warehouse Axial Equipment and the continuous improvement and evolution of the original products. We are committed to the pursuit of energy-saving, robust, comprehensive and innovative concepts. We have formed a high-quality professional scientific and technological research team.