'Efficiency, Sincerity and Down-to-earth working approach' to provide you with excellent service of processing for Mine Local Fan, Subway Tunnel Fan, high temperature blower fan. Your trust is the source of power for our development, and we will continue to move forward with the spirit of striving for advancement and determination to repay the society. We meet the needs of customers in various industries with world-leading technology, rich industry experience and thoughtful pre-sales, in-sales and after-sales services. Our company is based at home, looking at the world, actively carry out international business activities, participate in the world economic cycle and improve international competitiveness.
High-Pressure Centrifugal Ventilator:
Daily maintenance and common faults of High-Pressure Centrifugal Ventilator
1. Attention items in fan maintenance work:
①The fan can only operate under completely normal conditions.
②If the fan is started after maintenance, it is necessary to pay attention to whether all parts of the fan are normal.
③ Regularly remove impurities such as dust and dirt inside the fan and check the tightness of the belt at any time to prevent the belt from slipping.
④The maintenance of the fan must be carried out when the machine is stopped.
⑤ During the operation of the fan, if any abnormal phenomenon is found, it should be stopped immediately and checked.
⑥ Except that the grease should be replaced after each dismantling and repair, the grease should be replaced every six months under normal circumstances.

2. The main failure of the high-pressure centrifugal ventilator and its causes:
①The fan vibrates violently
a. The casing or the air inlet rubs against the impeller;
b. Loose or deformed impeller rivets;
c. The inlet and outlet pipes of the fan are poorly installed, causing resonance;
d. There is dust and dirt on the blades; the blades are worn; the impeller is deformed; the shaft is bent to make the rotor unbalanced
e. The positions of the two pulleys are not aligned. The coupling is installed incorrectly, and the centers on both sides of the coupling are not aligned; the position of the coupling changes after working for some time; the elastic components of the coupling are too deformed and worn too much.
②The bearing temperature rise is too high
a. The bearing box vibrates violently;
b. Bearing damage or shaft bending;
c. The grease is of poor quality or contains impurities.
d. The bearing is short of oil or the bearing is too oiled.
③The motor current is too large and the temperature rise is too high
a. The inlet and outlet pipes are not closed tightly when starting up;
b. Input voltage is too low or single-phase power failure;
c. The spindle speed exceeds the rated value;
d. The density of the input medium is too large or the temperature is too low.
e. The motor bearing is damaged; the bearing is short of oil or the oil is too much.
f. The system changes, resulting in a larger load on the fan and a larger load on the motor.

In the face of more fierce market competition, in order to win more seats in the market and further occupy the overseas market, our company constantly enriches the product line and introduces new FRP Exhaust Fan FRP Roof Fan. We have insisted on our production procedure innovation together with the most recent modern day managing method, attracting a sizable quantity of talents within this industry. Our company has all kinds of advanced equipment and production lines required as well as a group of experienced technical personnel and management personnel. Sophisticated testing equipment and strict quality management ensure the stability and continuous improvement of product quality.