Explosion Proof Mining Blower Axial Fan for Local Ventilation
We have high-quality and experienced technical development, production and operation management personnel, specializing in the development of high-quality and low-cost Anti-corrosion Axial Flow Fan, Highway Tunnel Ventilator, Ventilation Type Mining Fan. We win the market and repay the society with the business philosophy of 'integrity and pragmatism', enabling us to maintain steady and healthy development in an extremely competitive market, and achieve good economic and social benefits. Welcome customers to inquire and visit us! When It produced, it making use of the world's major method for reliable operation, a low failure price, it appropriate for Jeddah shoppers choice. 'Being a good adviser before sales and providing good service after sales' is our company's consistent service tenet. Our company adheres to the customer-centric service concept and is committed to providing customers with the best products and service. We believe that success comes from the professionalism, sincere service attitude and dedication of our employees. We are willing to develop and succeed together with our customers!
Mine explosion-proof blower The main technical performance parameters of this series of fans are: air volume Q, full pressure P, full pressure efficiency η, noise (compared with A sound level) LSA, rotating speed n and so on. The maximum efficiency of the series of fans is 86%, and the highest noise does not exceed 85dB(A). See Table 1 for details of other parameters.

This product can be placed flat on the floor of the roadway, and also can be suspended on the wall of the roadway for use. When used on the floor, the air inlet (the collector end) of the fan should not be immersed in water or cement. The gas temperature of the user environment of the fan is -20~50℃, and the altitude should not exceed 1000m. The rated frequency of the power supply used is 50 Hz, and the rated voltage is any class of 380V/660V or 660V/1140V.
The dust content of the gas passing through this product does not exceed 200mg/m3. It should be installed in the air inlet with a gas concentration of less than 1% in the underground coal mine. When the gas concentration exceeds 1%, the power supply should be cut off immediately.
Serial no. | Machine no. | Air volume (m3/min) | Full pressure (Pa) | Power (KW) |
1 | 3.5/4.4 | 133-90 | 715-1320 | 2.2×2 |
2 | 4/3 | 111-56 | 172-1800 | 1.5×2 |
3 | 4/4.4 | 136-72 | 251-1880 | 2.2×2 |
4 | 4/6 | 150-86 | 351-1956 | 3×2 |
5 | 5/8 | 210-120 | 331-2503 | 4×2 |
6 | 5/11 | 228-132 | 371-2950 | 5.5×2 |
7 | 5/15 | 245-150 | 380-3524 | 7.5×2 |
8 | 5.6/15 | 274-164 | 375-3750 | 7.5×2 |
9 | 5.6/22 | 340-210 | 405-4418 | 11×2 |
10 | 5.6/30 | 395-250 | 450-4470 | 15×2 |
11 | 6.3/30 | 420-260 | 413-4950 | 15×2 |
12 | 6.3/37 | 486-292 | 513-5130 | 18.5×2 |
13 | 6.3/44 | 525-310 | 600-5263 | 22×2 |
14 | 6.3/60 | 590-390 | 760-5800 | 30×2 |
15 | 7.1/60 | 620-396 | 603-6450 | 30×2 |
16 | 7.1/74 | 672-480 | 800-6500 | 37×2 |
17 | 7.1/90 | 738-400 | 1100-6700 | 45×2 |
18 | 8.2/74 | 630-270 | 420-6900 | 37×2 |
19 | 8.2/90 | 654-380 | 600-7600 | 45×2 |
20 | 8.2/110 | 790-550 | 680-8200 | 55×2 |
21 | 8.2/150 | 964-546 | 700-8600 | 75×2 |
22 | 10/60 | 1170-814 | 745-2733 | 30×2 |

We combine technological innovation with cost advantages, strive to create value for customers, and become an advanced solution provider in the Explosion Proof Mining Blower Axial Fan for Local Ventilation industry. Continuous product innovation to meet the individual needs of different customers is a problem that each company that intends to maintain competitiveness and sustainability in the market has to recognize. In the spirit of innovation, sincerity, unity, and enterprising.