Explosion-Proof and Intrinsically Safe Dual Power Vacuum Electromagnetic Starter for Coal Mine Fan
We can easily supply you with almost every type of product or service connected to our item variety for Boiler Induced Draft Fan, Mine Ventilation Blower, Mine Axial Fan. The success and development depend on the support and trust of customers. We adhere to the market-oriented, product quality as the life of the enterprise, we adhere to scientific innovation and strive to expand the application field of products. We are equipped with aggressive corporate management, active human resources, high-quality and perfect working environment, and continuous improvement. We strictly operate every proceduress in the production process, aiming to provide you with reliable products and quality services.
Coal mine explosion-proof fan FBCDZ (formerly BDK62) series of fans have a total of 24 machine numbers of NO.14-NO.44. To meet the needs of large and medium-sized mines with various kinds of ventilation network parameters, this series of fans are respectively equipped with 6, 8, 10, 12-pole three-phase asynchronous motors, and two different types of blade number gradations are adopted: that is, the total number of FBCDZ (formerly BDK62) (A) blades is Z = 32 pieces, and the total number of FBDCZ (formerly BDK62) (B) blades is Z = 24 pieces. Through the above combination, the FBCDZ (formerly BDK62) series of fans have a total of 90 specifications. It solves the problem that the main fan model of the mine is small and the selection is difficult.

The ground of the fan installation site should be flat, and according to the gauge in the sample schematic diagram, the auxiliary steel rail should be set, and the 24-38 Kg / M light rail can be selected and used. The steel rail can be pre-embedded on the cement floor surface or fixed on the sleeper.
The explosion-proof type of fan: the explosion-proof type for coal mine
If the motor power required in the early and the later stages of the mine is greatly different, it can be compared economically. In the early stage, two motors with smaller power are equipped, and in the later stage the motors are replaced with high-power ones. In this way, the motors can be operated under the condition of a higher power factor and higher efficiency, to reduce electricity consumption and save electricity costs.
The design service life of the FBCDZ (formerly BDK) series of fans is 20 years.
Series | No. | Air volume (m3/s) | Full pressure(Pa) | Motor model | Power (KW) |
FBCDZ(B)-8 (n=740r/min) | 27 | 63.7-161.0 | 1488-4313 | YBF560S2-8 | 2×355 |
28 | 71.1-179.8 | 1600-4638 | YBF560M2-8 | 2×450 | |
FBCDZ(B)-10 (n=590r/min) | 21 | 23.9-60.5 | 572-1659 | YBF315L-10 | 2×75 |
22 | 27.5-69.5 | 628-1820 | YBF315L-10 | 2×75 | |
23 | 31.4-79.5 | 686-1990 | YBF355M1-10 | 2×90 | |
24 | 35.7-90.3 | 747-2166 | YBF355M2-10 | 2×110 | |
25 | 40.3-102.1 | 811-2351 | YBF355L2-10 | 2×160 | |
26 | 45.4-114.8 | 877-2542 | YBF355L3-10 | 2×185 | |
27 | 50.8-128.6 | 946-2742 | YBF450S3-10 | 2×200 | |
28 | 56.7-143.4 | 1017-2949 | YBF450M2-10 | 2×250 | |
29 | 63.0-159.3 | 1091-3163 | YBF450M2-10 | 2×250 | |
30 | 69.7-176.4 | 1168-3385 | JBO710M1-10 | 2×315 | |
32 | 84.6-214.0 | 1329-3851 | JBO800S2-10 | 2×450 | |
34 | 101.5-256.7 | 1500-4348 | JBO900S1-10 | 2×560 | |
36 | 120.4-304.7 | 1682-4874 | JBO900M1-10 | 2×710 | |
FBCDZ(B)-12 (n=490r/min) | 25 | 33.5-84.8 | 559-1621 | JBO355S2-12 | 2×110 |
26 | 37.7-95.3 | 605-1754 | JBO355S2-12 | 2×110 | |
27 | 42.2-106.8 | 652-1891 | JBO400S-12 | 2×132 | |
28 | 47.1-119.1 | 702-2034 | JBO400M-12 | 2×160 | |
29 | 52.3-132.3 | 753-2182 | JBO400M-12 | 2×160 | |
30 | 57.9-146.5 | 806-2335 | JBO710S1-12 | 2×200 | |
32 | 70.3-177.7 | 916-2656 | JBO710M1-12 | 2×250 | |
34 | 84.3-213.2 | 1035-2999 | JBO800S1-12 | 2×315 | |
36 | 100.0-253.1 | 1160-3362 | JBO900S1-12 | 2×450 | |
38 | 117.6-297.6 | 1292-3746 | JBO900M1-12 | 2×560 | |
40 | 137.2-347.2 | 1432-4150 | JBO900M2-12 | 2×710 | |
42 | 158.8-401.9 | 1579-4576 | JBO900L2-12 | 2×1000 | |
44 | 182.6-462.1 | 1733-5022 | JBO900L3-12 | 2×1250 |

With the persistent pursuit of the cause and the courage to challenge ourselves forever, we will continue to innovate and create better Explosion-Proof and Intrinsically Safe Dual Power Vacuum Electromagnetic Starter for Coal Mine Fan to thank new and old customers for their love. Our group through specialist training. We have set up a strict quality control system.