We have many excellent staff members good at marketing, QC, and dealing with kinds of troublesome problem in the production process for Submarine Tunnel Fan, Mine Explosion-proof Induced Draft Fan, Mine-to-spin Pressurized Fan. We take 'innovative development and win-win cooperation' as our business philosophy and 'respect customers and return customers' as our service motto. Through strict management and standardized operation, we can provide customers with perfect after-sales service. In the fierce market competition, we insist on stable products, dedicated and sincere service, and the principle of customer first.
Structural characteristics of boiler-induced draft fan applications.
Product model | Rotate speed r/min | No. | Full pressure Pa | Flow m3 / h | Motor machine | ||||||
Model | Power kW | ||||||||||
G4-68 № 8 D | 1450 | 1 | 2178~1481 | 16985~30134 | Y180M-4 | 18.5 | |||||
G4-68 № 9 D | 1450 | 1 | 2757~1874 | 24183~42906 | Y200L-4 | 30 | |||||
960 | 1 | 1207~824 | 16011~28407 | Y160L-6 | 11 | ||||||
G4-68 № 10 D | 1450 | 1 | 3404~2315 | 33173~58856 | Y250M-4 | 55 | |||||
960 | 1 | 1491~1010 | 21963~38966 | Y180L-6 | 15 | ||||||
730 | 1 | 863~589 | 16701~29631 | Y160L-8 | 7.5 | ||||||
G4-68 №11.2 D | 1450 | 1 | 4277~2904 | 46606~82688 | Y280M-4 | 90 | |||||
960 | 1 | 1874~1275 | 30856~54745 | Y225M-6 | 30 | ||||||
730 | 1 | 1079~736 | 23464~41629 | Y180L-8 | 11 | ||||||
G4-68 №12.5 D | 1450 | 1 | 5327~3620 | 64791~114952 | Y315L1-4 | 160 | |||||
960 | 1 | 2335~1589 | 42896~76106 | Y280S-6 | 45 | ||||||
730 | 1 | 1354~912 | 32619~57872 | Y225M-8 | 22 | ||||||
G4-68 № 14 D | 1450 | 1 | 6681~6327 | 91027~114518 | Y355M2-4 | 250 | |||||
2 | 6023~4532 | 126263~161499 | Y355L2-4 | 315 | |||||||
960 | 1 | 2923~2776 | 60266~75819 | Y315S-6 | 75 | ||||||
2 | 2639~1991 | 83595~106924 | Y315M1-6 | 90 | |||||||
730 | 1 | 1697~1148 | 45827~81307 | Y280S-8 | 37 | ||||||
G4-68 № 16 D | 960 | 1 | 3826~2600 | 89960~159606 | Y355M1-6 | 160 | |||||
730 | 1 | 2207~1501 | 68407~121367 | Y315M1-8 | 75 | ||||||
580 | 1 | 1393~952 | 54351~96429 | Y315S-10 | 45 | ||||||
Product model | Rotate speed r/min | No. | Full pressure Pa | Flow m3 / h | Motor machine | ||||||
Model | Power kW | ||||||||||
Y4-68 № 8 D | 1450 | 1 | 1540~1059 | 15889~29038 | Y160L-4 | 15 | |||||
Y4-68 № 9 D | 1450 | 1 | 1952~1844 | 22623~28864 | Y180L-4 | 22 | |||||
2 | 1756~1344 | 31984~41345 | Y200L-4 | 30 | |||||||
960 | 1 | 853~589 | 14978~27374 | Y160M-6 | 7.5 | ||||||
Y4-68 № 10 D | 1450 | 1 | 2413~1658 | 31033~56715 | Y225M-4 | 45 | |||||
960 | 1 | 1059~726 | 20546~37549 | Y180L-6 | 15 | ||||||
730 | 1 | 608~422 | 15623~28553 | Y160M2-8 | 5.5 | ||||||
Y4-68 №11.2 D | 1450 | 1 | 3021~2080 | 43599~79681 | Y250S-4 | 75 | |||||
960 | 1 | 1324~912 | 28866~52754 | Y200L2-6 | 22 | ||||||
730 | 1 | 765~530 | 21950~40115 | Y180L-8 | 11 | ||||||
Y4-68 №12.5 D | 1450 | 1 | 3767~3561 | 60611~77331 | Y315S-4 | 110 | |||||
2 | 3394~2590 | 85692~110772 | Y315M-4 | 132 | |||||||
960 | 1 | 1648~1138 | 40129~73339 | Y250M-6 | 37 | ||||||
730 | 1 | 952~657 | 30515~55768 | Y225S-8 | 18.5 | ||||||
Y4-68 № 14 D | 1450 | 1 | 4728~3247 | 85154~155627 | Y355M2-4 | 250 | |||||
960 | 1 | 2070~1422 | 56378~103036 | Y315S-6 | 75 | ||||||
730 | 1 | 1197~824 | 42871~78350 | Y250M-8 | 30 | ||||||
Our goal is to offer our customers the best service relying on science and technology, developing and producing more high-quality Best Price Boiler Matching Induced Draft Blower Fan. Our products are sold all over the world and are favored by new and old customers. We sincerely hope to establish a good cooperative relationship with our customers, and to provide them with qualified and satisfactory products is our eternal goal. The successful of our company is inseparable from the understanding and support of friends from all walks of life in the society, as well as the care and favor of new and old customers for many years.