Axial Fan/ Wall Fan/ FRP Industrial Fan/ Wall Mounted Industrial Fan
Our extraordinary customization capabilities and extensive collaborative development with customers make us develop well in the Mine Main Fan-extraction Type, Coal Mine Explosion-proof Blower, Main Ventilation Machine In Mine industry. We have established a good and stable partnership with many well-known brand enterprises. Customers from all walks of life are welcome to come to the factory for communication, visit and guidance. Since the establishment of our company, our company has grown from scratch, from weak to strong, the staff of the whole plant are conscientious and work hard, and the scale of the company is constantly expanding.
Wall Axial Fan:
It is suitable for ventilation in workshops, warehouses and laboratories, etc. Its explosion-proof series is suitable for ventilation in a flammable and explosive gas environment.

The Profile of Wall Axial Fan:
(1) T30 (03-11, 30K4) axial flow ventilator can be used widely for ventilation in factories, warehouses, offices and houses, or used for enhancing heat dissipation of heating. If the case is removed, it can be used as a free fan, or it can be installed in series in a long exhaust pipe to increase the wind pressure in the pipe.
There are 46 types of this ventilator, among which there are 9 machine numbers of 3 blades, 6 blades, 8 blades and 9 blades. According to the diameter of the impeller, the order that is arranged from small to large is: №3, №3.5, №4, №5, №6, №7, №8, №9 and №10;There are 10 machine numbers of 4 blades. According to the diameter of the impeller, the order that is arranged from small to large is: №2.5, №3, №3.5, №4, №5, №6, №7, №8, №9 and №10.
This ventilator consists of three parts: an impeller, a case and a wind collector:
The impeller consists of blades and wheel hub and so on. The blade is welded to the outer circumference of the wheel hub with a thin steel plate according to the required mounting angle. The impeller case ratio (the ratio of shaft disk diameter to impeller diameter) is (-)=0.3.
All of the blades are stamped into similar shapes. For the mounting angle, 3 blades are divided into five types of 10 degrees, 15 degrees, 20 degrees and 35 degrees; 4 blades, 6 blades and 8 blades are divided into five types of 15 degrees, 20 degrees, 25 degrees, 30 degrees and 35 degrees. The impeller is directly mounted on the motor shaft, of which №3 to №8adopt two kinds of motor rotation speeds, while №9 and №10 adopt a kind of motor rotation speed. The air volume ranges from 550 to 49,500 m3/h and the wind pressure ranges from 25 to 505 Pa.
The case part is composed of a wind cylinder and a bottom frame, etc., while the bottom frame is divided into two types that are made of thin steel plate or proximate matter.
Air collector part: The air collector is a circular streamline, which is stamped from a thin steel plate, to reduce airflow inlet loss.
Model | Machine No. | Full pressure (Pa) | Flow (m3/h) | Matched motor model(KW) |
T30(4) | 5 | 126 | 7500 | 4-0.55 |
130 | 8550 | 4-0.75 | ||
51 | 2780 | 6-0.75 | ||
51 | 3640 | 6-0.75 | ||
55 | 4340 | 6-0.75 | ||
57 | 5040 | 6-0.75 | ||
58 | 5730 | 6-0.75 | ||
6 | 167 | 7250 | 4-0.75 | |
167 | 9500 | 4-0.75 | ||
178 | 11300 | 4-1.1 | ||
185 | 13100 | 4-1.5 | ||
190 | 15000 | 4-2.2 | ||
74 | 4800 | 6-0.75 | ||
74 | 6300 | 6-0.75 | ||
78 | 7500 | 6-0.75 | ||
81 | 8700 | 6-0.75 | ||
83 | 9900 | 6-0.75 | ||
7 | 228 | 11500 | 4-1.5 | |
228 | 15100 | 4-2.2 | ||
243 | 18000 | 4-2.2 | ||
253 | 20900 | 4-3 | ||
259 | 23800 | 4-4 |
Model | Machine No. | Full pressure (Pa) | Flow (m3/h) | Matched motor model(KW) |
T30(4) | 8 | 93 | 7650 | 6-0.75 |
93 | 10100 | 6-0.75 | ||
98 | 12000 | 6-0.75 | ||
103 | 13900 | 6-1.1 | ||
105 | 15800 | 6-1.1 | ||
294 | 17300 | 4-3 | ||
294 | 22700 | 4-4 | ||
314 | 27000 | 4-5.5 | ||
323 | 31300 | 4-5.5 | ||
333 | 35600 | 4-7.5 | ||
130 | 11400 | 6-0.75 | ||
130 | 14900 | 6-1.1 | ||
139 | 17800 | 6-1.5 | ||
145 | 20600 | 6-2.2 | ||
150 | 23500 | 6-2.2 | ||
9 | 165 | 16200 | 6-1.5 | |
165 | 21200 | 6-2.2 | ||
176 | 25200 | 6-2.2 | ||
183 | 29400 | 6-3 | ||
186 | 33400 | 6-4 | ||
10 | 206 | 22600 | 6-3 | |
206 | 29700 | 6-3 |

Wall Axial Fan is generally used in factories, warehouses, offices, residences, ventilation or strengthening heating and heat dissipation, axial fans as a very common fan, according to the survey is very common in life or processing and production, and the scope of use has been constantly expanding.
We're also concentrating on improving the things administration and QC program to ensure we could maintain terrific gain from the fiercely-competitive company for Axial Fan/ Wall Fan/ FRP Industrial Fan/ Wall Mounted Industrial Fan. Up to now, our company has developed into a mature company based on independent research and technological development and oriented to the market such as accumulation, continuous innovation. We develop the market with quality and win support with integrity.
You Might Also Like