1500W Three Phase Axial Flow Ducting Wall Fan

1500W Three Phase Axial Flow Ducting Wall Fan

Wall axial fan It is suitable for the ventilation in the workshops, warehouses and laboratories, etc. Its explosion-proof series is suitable for the ventilation in flammable and explosive gas environment. Profile (1) T30 (03-11, 30K4) axial flow ventilator can be used widely for ventilation in...
Send Inquiry
Product Introduction

We hope to develop more humane products, and continuously inject high-quality and humanistic spirit into every Medium Pressure Centrifugal Fan, Sawdust Conveyor Fan, Centrifugal Blower Fan we develop. All along, we adhere to the customer-oriented, market-oriented, constantly improve product quality and develop product types to meet the growing needs of customers. We will constantly surpass ourselves and realize corporate value. We have a wide-area company network system to provide customers with timely and efficient pre-sales and after-sales services.

Wall Axial Fan:

It is suitable for ventilation in workshops, warehouses and laboratories, etc. Its explosion-proof series is suitable for ventilation in a flammable and explosive gas environment.

2


The Profile of Wall Axial Fan:

(1) T30 (03-11, 30K4) axial flow ventilator can be used widely for ventilation in factories, warehouses, offices and houses, or used for enhancing heat dissipation of heating. If the case is removed, it can be used as a free fan, or it can be installed in series in a long exhaust pipe to increase the wind pressure in the pipe.

There are 46 types of this ventilator, among which there are 9 machine numbers of 3 blades, 6 blades, 8 blades and 9 blades. According to the diameter of the impeller, the order that is arranged from small to large is: №3, №3.5,  №4, №5, №6, №7, №8, №9 and №10There are 10 machine numbers of 4 blades. According to the diameter of the impeller, the order that is arranged from small to large is: №2.5, №3, №3.5, №4, №5, №6, №7, №8, №9 and №10.


This ventilator consists of three parts: an impeller, a case and a wind collector:

The impeller consists of blades and wheel hub and so on. The blade is welded to the outer circumference of the wheel hub with a thin steel plate according to the required mounting angle. The impeller case ratio (the ratio of shaft disk diameter to impeller diameter) is (-)=0.3.


All of the blades are stamped into similar shapes. For the mounting angle, 3 blades are divided into five types of 10 degrees, 15 degrees, 20 degrees and 35 degrees; 4 blades, 6 blades and 8 blades are divided into five types of 15 degrees, 20 degrees, 25 degrees, 30 degrees and 35 degrees. The impeller is directly mounted on the motor shaft, of which №3 to №8adopt two kinds of motor rotation speeds, while №9 and №10 adopt a kind of motor rotation speed. The air volume ranges from 550 to 49,500 m3/h and the wind pressure ranges from 25 to 505 Pa.


The case part is composed of a wind cylinder and a bottom frame, etc., while the bottom frame is divided into two types that are made of thin steel plate or proximate matter.


Air collector part: The air collector is a circular streamline, which is stamped from a thin steel plate, to reduce airflow inlet loss.


Model

Machine    No.

Full pressure (Pa)

Flow (m3/h)

Matched motor    model(KW)

T30(4)

5

126

7500

4-0.55

130

8550

4-0.75

51

2780

6-0.75

51

3640

6-0.75

55

4340

6-0.75

57

5040

6-0.75

58

5730

6-0.75

6

167

7250

4-0.75

167

9500

4-0.75

178

11300

4-1.1

185

13100

4-1.5

190

15000

4-2.2

74

4800

6-0.75

74

6300

6-0.75

78

7500

6-0.75

81

8700

6-0.75

83

9900

6-0.75

7

228

11500

4-1.5

228

15100

4-2.2

243

18000

4-2.2

253

20900

4-3

259

23800

4-4



Model

Machine No.

Full pressure (Pa)

Flow (m3/h)

Matched motor    model(KW)

T30(4)

8

93

7650

6-0.75

93

10100

6-0.75

98

12000

6-0.75

103

13900

6-1.1

105

15800

6-1.1

294

17300

4-3

294

22700

4-4

314

27000

4-5.5

323

31300

4-5.5

333

35600

4-7.5

130

11400

6-0.75

130

14900

6-1.1

139

17800

6-1.5

145

20600

6-2.2

150

23500

6-2.2

9

165

16200

6-1.5

165

21200

6-2.2

176

25200

6-2.2

183

29400

6-3

186

33400

6-4

10

206

22600

6-3

206

29700

6-3


5

Wall Axial Fan is generally used in factories, warehouses, offices, residences, ventilation or strengthening heating and heat dissipation, axial fans as a very common fan, according to the survey is very common in life or processing and production, and the scope of use has been constantly expanding. 


We not only will try our greatest to offer superb companies to just about every buyer, but also are ready to receive any suggestion offered by our shoppers for 1500W Three Phase Axial Flow Ducting Wall Fan. Our company has always followed the operating system of product quality first. Over the years, our business has reached stability, health and rapid development with the support and assistance of our customers from all walks of life.