The startup of the high-temperature centrifugal fan we explained today mainly refers to the startup of its motor. Many users do not know much about this. Next, we will introduce it in detail:
1. Equipped with a fixed-frequency ordinary motor, using star-delta or auto-coupling step-down starting, which is an economical and simple starting method for high-temperature centrifugal fans. When the fan starts, close the damper, and when the fan reaches the rated speed, gradually open the damper. As the temperature of the medium rises, it is all turned on. It should be noted here that the design parameters of the high-temperature fan and the matching motor are based on high-temperature design. However, in the initial stage of the fan operation, the gas in the pipeline is generally at room temperature, and the gas molecule density is large. , The quality per unit volume is high, so the initial load of the fan will be relatively large, and the function of the damper is not to adjust the air volume, but to prevent the current as a spare part.
2. Equipped with a fixed frequency ordinary motor and start it with a frequency converter. This method is suitable for the working conditions where the flow rate does not need to be adjusted frequently during the use of the high-temperature centrifugal fan. When starting, the motor is started at a lower frequency first, and the frequency of the motor is increased as the air inlet temperature of the fan continues to increase. It will cause motor load, and the widespread use of frequency converters makes the damper take a back seat. Although the use of frequency converters will increase the purchase cost, it has a good protective effect on the motor. In the debugging stage, the air volume can be adjusted freely. , easy to debug the whole system. But the adjustment range is limited, and the adjustment range is between 40-50hz.
3. Equipped with frequency conversion motor, use frequency conversion to start and run. This method has high purchase cost but low operating cost. It is more suitable for high-temperature centrifugal fans that often need to adjust the air volume. The adjustment range is more willful to 0-60hz. Some customer systems design the fan to start every day. More than a dozen times, it is undoubtedly a kind of torture for fixed-frequency motors. High starting current often leads to premature degradation, and the life of the motor will be greatly shortened. Therefore, the use of variable-frequency motors does not have the above shortcomings. The three startup methods of the high-temperature centrifugal fan have their own advantages and disadvantages, and the user can make an appropriate choice according to the economic cost estimate.