After the fan impeller rotates for a long time, various corrosion and wear will inevitably occur. Generally, it is divided into: impeller corrosion, impeller wear, impeller dust adhesion, impeller high temperature gas. Below, the editor of Jiuzhou Pratt & Whitney will share with you the treatment measures for various types of damage:
1. Corrosion treatment measures
Corrosion of fans is relatively common. It not only occurs in fans that transport corrosive gases such as CO2 gas and chlorine gas, but also in fans that process the atmosphere containing various exhaust gases. Unpredictable corrosion will also occur at any time.
The treatment measures that should be taken when the impeller is corroded are as follows:
1) Re-analyze the composition of the gas medium and the materials used.
2) In addition to being in a dry state, CO2 gas and chlorine gas have almost no materials that can resist their corrosion. Therefore, check the poor operation of the mixed water, etc., and take measures to deal with them.
3) Check the shedding of the anti-corrosion coating material.
The types of cladding materials include thin stainless steel plates, liquid metal spraying, metal cladding materials composed of metal spraying, and non-metallic cladding materials composed of paint, rubber, vinyl resin, etc.
When the rotor is unbalanced and excessive vibration is caused due to corrosion, ordinary steel is often used for emergency compensation. However, because the impeller of the fan is a rotating body, it needs to be replaced with a wear-resistant and corrosion-resistant metal material as a cladding material as soon as possible.
2. Wear and tear treatment measures
When the impeller of the powder conveying fan is seriously worn, it should be regarded as a wearing part.
Such as: exhaust fans for combustion furnaces in iron and steel plants, various exhaust fans for cement plants, and fans for conveying various powders.
In addition, the fans for boiler exhaust are gradually belonging to the models that need to take anti-wear measures.
In order to reduce wear, it is necessary to take measures such as reducing the amount of dust or optimizing the form of the impeller, but the method of reducing the peripheral speed of the impeller is the most effective way.
As a way to prolong the service life of wearing parts, the following wear-resistant measures can be taken:
1) Make a blade with a scaly section.
2) Hard chrome plating or sputtering hard metal layer.
3) Overlay welding with a hard electrode.
4) Install the liner (it can be replaced after wear).
The above measures are all ways to prolong the service life of the impeller.
During regular maintenance, it is best to check its wear and tear frequently so as to prepare for repairs in advance.
3. Dust adhesion treatment measures
Since the dust in the gas will adhere to the blades, it will inevitably hinder the airflow, thereby reducing the air volume, reducing the efficiency, or causing excessive vibration due to the uneven shedding of the attachments and attachments.
Its treatment measures are:
1) Choose a blade form that is difficult to adhere to dust, such as: using a backward blade.
2) Take measures to remove attachments.
There are several ways to remove attachments:
1) Regular and intermittent cleaning with water.
2) Using a mechanical removal device, the attachments can be partially removed.
3) By blowing hot air and cold air to form a temperature difference.
4) The method of spraying powder particles.
In short, in today's energy-saving era, it is worthwhile to work hard to maximize the long-term operation under high-efficiency conditions.
4. High temperature gas treatment measures
When the medium is high temperature gas, it can be solved by selecting heat-resistant materials.
Because the high temperature gas is generally combustion exhaust gas, there are many accidents caused by corrosion and wear.
There are also a few accidents due to the poor operation of the equipment, which caused the temperature of the gas medium to rise sharply once, so that the impeller is deformed to a degree that is difficult to use for a long time due to the creep phenomenon, and the dew condensation due to the temperature drop, and even increase the corrosion situation.
Considering the obvious creep phenomenon of carbon steel when it is close to 400℃, in order to prolong the service life of the fan, it is necessary to fully work on the operation range and operation management.