Exhaust Mining Counter-Rotating Main Ventilator Fan
Exhaust Mining Counter-Rotating Main Ventilator Fan is uncommonly planned by the requirements of different non-coal mineshaft ventilation, like metallurgy, nonferrous metals, gold, synthetics, building materials, and atomic industry, and so forth, which can be utilized as a primary fan and helper fan. It very well may be introduced on a superficial level or underground, reasonable for the joined activity of numerous fans, which is an ideal machine station ventilator for different machine stations in the ventilation arrangement of the multi-fan series multi-stage machine station. It is additionally reasonable for ventilation in enormous studios, burrows, common air protection projects, and so on.
The features of the Exhaust Mining Counter-Rotating Main Ventilator Fan
Counter-Rotating Design: Engineered with precision, our ventilator fan utilizes a unique counter-rotating mechanism, optimizing airflow efficiency and ensuring maximum ventilation in mining environments.
High Performance: Built to deliver exceptional performance even in the most challenging conditions, our ventilator fan provides reliable and consistent airflow to maintain a safe and comfortable working environment for miners.
Robust Construction: Crafted from high-quality materials and subjected to rigorous testing, our ventilator fan boasts unmatched durability and resilience, making it capable of withstanding the harsh conditions of mining operations.
Energy Efficiency: With a focus on sustainability, our ventilator fan is designed to minimize energy consumption while maximizing airflow, helping mining operations reduce their environmental footprint and operating costs.
Easy Installation and Maintenance: Engineered for convenience, our ventilator fan features a user-friendly design for hassle-free installation and maintenance, ensuring minimal downtime and maximum productivity.
At the point when utilized as the principal fan and the station fan, the Exhaust Mining Counter-Rotating Main Ventilator Fan ought to be outfitted with a unique diffuser. The fundamental fan on a superficial level will be outfitted with a diffuser to change over one piece of the unique tension into static strain and lessen the powerful strain, and loss of the power source, to accomplish the reason for energy saving. The ventilator introduced in the well will be outfitted with a diffuser, which not exclusively can decrease the neighborhood obstruction coefficient, yet additionally can diminish the unique tension worth of the diffuser outlet, in this manner enormously lessening the nearby opposition of the fan gadget and saving ventilation power utilization.
All of the Exhaust Mining Counter-Rotating Main Ventilator Fan are outfitted with unique supporting diffusers. The spine of the diffuser is fixed to the rib of the fan outlet with the bolt.
The engine applied for the Exhaust Mining Counter-Rotating Main Ventilator Fan is typically a Y series three-stage nonconcurrent engine with an evaluated voltage of 380V and a security class of IP54 (ie shut type), which can be completely adjusted to the immediate drive and introduced in the mine to move the air holding back firearm smoke, dust and the air with high stickiness.
The supporting exceptional security starter cupboard of the Exhaust Mining Counter-Rotating Main Ventilator Fan
As indicated by the requirements of clients, the ventilator of every determination can be provided with an exceptional insurance starter bureau when it is conveyed from the processing plant. The electronic control gadget can dependably safeguard the engine from the issues, like over-burden, voltage misfortune, shortcircuits, and so forth. A gadget that can rapidly invert the engine is set for it. At the point when the ventilator is expected to switch the upset breeze, press the stop button first, and afterward press the converse button after the ventilator stops.
The Exhaust Mining Counter-Rotating Main Ventilator Fan is a steel plate welded structure, which can't be exposed to enormous effect during transportation to forestall the distortion of the case and the cutting edge to be stuck. Ventilators with a machine number more prominent than 14 are for the most part delivered in a design that can be dismantled all over. At the point when the ventilator is introduced in the well assuming the cross-sectional region of the well is little, the upper and lower portions of the case, wheel center, engine, and so forth. Can be dismantled and shipped independently. On the off chance that the cross-sectional region of the well is enormous, it is smarter to ship it without dismantling it however much as could reasonably be expected to work with the underground establishment.
The usage and maintenance of the Exhaust Mining Counter-Rotating Main Ventilator Fan
- Underground Mining
- Surface Mining
- Tunneling
- Excavation Sites
- Industrial Ventilation
Exhaust Mining Counter-Rotating Main Ventilator Fan parameter selection table
| Model | Machine No. | Air volume (m3/s) | Full pressure (Pa) | Motor model | Power (KW) |
DK40-6 |
15 | 18.2-43.6 | 382-1690 | Y250M-6 | 2×37 |
| 16 | 22.1-52.9 | 435-1923 | Y280M-6 | 2×55 | |
| 17 | 26.5-63.5 | 491-2171 | Y315S-6 | 2×75 | |
| 18 | 31.5-75.4 | 551-2433 | Y315M-6 | 2×90 | |
| 19 | 37.0-88.6 | 614-2711 | Y315 L2-6 | 2×132 | |
| 20 | 43.2-103.4 | 680-3004 | Y355M1-6 | 2×160 | |
| 21 | 50.0-119.7 | 750-3312 | Y355M3-6 | 2×200 | |
DK40-8 |
18 | 23.5-56.1 | 306-1350 | Y280S-8 | 2×37 |
| 19 | 27.6-66.0 | 341-1504 | Y315S-8 | 2×55 | |
| 20 | 32.2-77.0 | 377-3334 | T315M-8 | 2×75 | |
| 21 | 37.3-89.1 | 416-1838 | Y315 L1-8 | 2×90 | |
| 22 | 42.8-102.5 | 457-2017 | Y315 L2-8 | 2×110 | |
| 23 | 48.9-117.1 | 499-2204 | Y355 M1-8 | 2×132 | |
| 24 | 55.6-133.0 | 543-2400 | Y355 M2-8 | 2×160 | |
| 25 | 62.9-150.4 | 589-2605 | Y355 L2-8 | 2×200 | |
DK45-6 |
12 | 10.7-27.6 | 698-1374 | Y200 L2-6 | 2×22 |
| 13 | 13.6-35.0 | 819-1613 | Y250 M-6 | 2×37 | |
| 14 | 17.0-43.8 | 950-1871 | Y280M-6 | 2×55 | |
| 15 | 20.9-53.8 | 1091-2148 | Y315S-6 | 2×75 | |
| 16 | 25.4-65.3 | 1241-2444 | Y315M-6 | 2×90 | |
| 17 | 30.4-78.3 | 1400-2759 | Y315 L2-6 | 2×132 | |
| 18 | 36.1-93.5 | 1570-3093 | Y355 M1-6 | 2×160 | |
| 19 | 42.5-109.4 | 1750-3446 | Y355 M3-6 | 2×200 | |
| 20 | 49.5-127.6 | 1939-3819 | Y355 L2-6 | 2×250 | |
| DK45-8 | 16 | 18.9-48.7 | 688-1356 | Y280S-8 | 2×37 |
| 17 | 22.7-58.4 | 777-1531 | Y315S-8 | 2×55 |
DK45-8 |
18 | 26.9-69.3 | 871-1716 | Y315M-8 | 2×75 |
| 19 | 31.6-81.5 | 971-1912 | Y315 L1-8 | 2×90 | |
| 20 | 36.9-95.1 | 1076-2119 | Y315 L2-8 | 2×110 | |
| 21 | 42.7-110.1 | 1186-2336 | Y355 M2-8 | 2×160 | |
| 22 | 49.1-126.6 | 1302-2563 | Y355L2-8 | 2×200 |
Detailed Photos


Why Choose Zibo Hengding Fan Co., Ltd.?
With nearly two decades of experience in manufacturing high-quality ventilation solutions, Zibo Hengding Fan Co., Ltd. is your trusted partner for all your mining ventilation needs. Backed by a team of skilled professionals and a commitment to excellence, we strive to deliver innovative products that exceed expectations and enhance safety and productivity in mining operations worldwide.
Invest in Quality. Invest in Safety. Choose Zibo Hengding Fan Co., Ltd. for Your Ventilation Needs.
Hot Tags: Exhaust Mining Counter-Rotating Main Ventilator Fan, China, manufacturers, suppliers, factory, price, for sale, CE certification, mini centrifugal fan, cabinet centrifugal fan, inline centrifugal fan, centrifugal air blower, centrifugal upblast exhaust fan, high temp fan
You Might Also Like
Send Inquiry